Automated Logic OptiPoint™ Smart Valves provide precise hot water flow control for pressure-dependent HVAC applications, including zoning reheat systems. Featuring communicating actuators, these smart valves allow Automated Logic terminal unit controllers to modulate valve positions directly through serial commands, delivering precise control and exact position feedback for diagnostics.
Designed to integrate with Act Net-enabled controllers, OptiPoint Smart Valves eliminate the need for physical controller inputs and outputs. Up to two valves can connect to the Act Net bus on a compatible controller, and each valve is pre-addressed to simplify installation and commissioning.
Available with electronic fail-safe options that drive the valve to an open, closed, or last-position state during power loss, OptiPoint valves offer flexible control to meet specific application requirements. Field-adjustable maximum flow coefficients (Cv) allow local or remote configuration through the WebCTRL building automation system.
Featuring self-cleaning ball valve technology, high close-off capabilities, and a patented brushless DC motor, OptiPoint Smart Valves help minimize energy losses, prevent clogging, and improve long-term reliability. Exact position feedback and remote accessibility through WebCTRL support commissioning, fault detection, diagnostics, and ongoing maintenance.
Designed for chilled or hot water applications with up to 60% glycol, OptiPoint Smart Valves provide an efficient solution for precise HVAC reheat control and building automation integration.
Key Features & Benefits
Features:
- • Communicating actuators provide direct serial control through Act Net-enabled terminal unit controllers.
- • Supports up to two valves connected to the Act Net bus on a compatible controller.
- • Pre-addressed valves simplify installation and commissioning.
- • Eliminates the need for physical controller inputs and outputs for connected valves.
- • Electronic fail-safe options drive the actuator to the open, closed, or last-position state during power loss, depending on model.
- • Exact valve position feedback communicates to the WebCTRL building automation system over Act Net.
- • Remote access through WebCTRL supports diagnostics and fault detection.
- • Field-adjustable maximum flow coefficient (Cv), configurable locally or remotely through WebCTRL.
- • Self-cleaning ball valve technology helps minimize clogging and energy losses.
- • High close-off capability provides 0% A–AB leakage.
- • Equal-percentage flow characteristics for 2-way valves.
- • Linear flow characteristics for 3-way valves.
- • Patented brushless DC motor helps prevent stalled-motor failures and extend actuator life.
- • Snap-fit valve body and actuator connection enables tool-free installation and simplifies retrofits.
- • Extended valve stem allows actuator removal without damaging surrounding pipe insulation.
- • Power supply: 24 VAC/DC.
- • Electrical connection: 3 ft (1 m) cable.
- • Transformer sizing: 8 VA.
- • Power consumption:
- - Fail-safe: 2.5 W running and 0.5 W holding.
- - Fail-last-position: 0.6 W running and 0.4 W holding.
- • Available nominal sizes: 1/2" and 3/4".
- • Female NPT connections.
- • Compatible with chilled or hot water containing up to 60% glycol.
- • Media temperature range: 36–212°F (2–100°C).
- • Media temperature limit: 250°F (120°C).
- • Maximum allowable operating temperature: 212°F (100°C).
- • Body pressure rating: 360 psi.
- • Close-off pressure: 75 psi.
- • Maximum differential pressure: 40 psi.
- • Valve body material: forged brass.
- • Ball material: chrome-plated brass.
- • Stem material: brass.
- • Seats: Teflon® PTFE.
- • O-rings: lubricated EPDM.
Benefits:
- • Communicating actuators provide direct serial control through Act Net-enabled terminal unit controllers.
- • Supports up to two valves connected to the Act Net bus on a compatible controller.
- • Pre-addressed valves simplify installation and commissioning.
- • Eliminates the need for physical controller inputs and outputs for connected valves.
- • Electronic fail-safe options drive the actuator to the open, closed, or last-position state during power loss, depending on model.
- • Exact valve position feedback communicates to the WebCTRL building automation system over Act Net.
- • Remote access through WebCTRL supports diagnostics and fault detection.
- • Field-adjustable maximum flow coefficient (Cv), configurable locally or remotely through WebCTRL.
- • Self-cleaning ball valve technology helps minimize clogging and energy losses.
- • High close-off capability provides 0% A–AB leakage.
- • Equal-percentage flow characteristics for 2-way valves.
- • Linear flow characteristics for 3-way valves.
- • Patented brushless DC motor helps prevent stalled-motor failures and extend actuator life.
- • Snap-fit valve body and actuator connection enables tool-free installation and simplifies retrofits.
- • Extended valve stem allows actuator removal without damaging surrounding pipe insulation.
- • Power supply: 24 VAC/DC.
- • Electrical connection: 3 ft (1 m) cable.
- • Transformer sizing: 8 VA.
- • Power consumption:
- - Fail-safe: 2.5 W running and 0.5 W holding.
- - Fail-last-position: 0.6 W running and 0.4 W holding.
- • Available nominal sizes: 1/2" and 3/4".
- • Female NPT connections.
- • Compatible with chilled or hot water containing up to 60% glycol.
- • Media temperature range: 36–212°F (2–100°C).
- • Media temperature limit: 250°F (120°C).
- • Maximum allowable operating temperature: 212°F (100°C).
- • Body pressure rating: 360 psi.
- • Close-off pressure: 75 psi.
- • Maximum differential pressure: 40 psi.
- • Valve body material: forged brass.
- • Ball material: chrome-plated brass.
- • Stem material: brass.
- • Seats: Teflon® PTFE.
- • O-rings: lubricated EPDM.