OptiFlex I/O expanders provide additional input and output capacity for OptiFlex BACnet Building Controllers. Up to nine I/O expanders can be added to a single OptiFlex BACnet Building Controller. Designed for flexible installation, the expanders support DIN rail or screw-tab mounting and can be combined to meet the specific input and output requirements of the equipment being controlled. They can be mounted directly to an OFBBC controller or installed remotely up to 500 feet away.

OptiFlex I/O expanders provide additional input and output capacity for OptiFlex BACnet Building Controllers. Up to nine I/O expanders can be added to a single OptiFlex BACnet Building Controller. Designed for flexible installation, the expanders support DIN rail or screw-tab mounting and can be combined to meet the specific input and output requirements of the equipment being controlled. They can be mounted directly to an OFBBC controller or installed remotely up to 500 feet away.

Key Features & Benefits

Features:

  • - Available in four models: FIO48u, FIO88u, FIO812u, and FIO012u.
  • - FIO48u provides 4 universal outputs and 8 universal inputs.
  • - FIO88u provides 8 universal outputs and 8 universal inputs.
  • - FIO812u provides 8 universal outputs and 12 universal inputs.
  • - FIO012u provides 0 universal outputs and 12 universal inputs.
  • - Supports the addition of up to nine I/O expanders per OptiFlex BACnet Building Controller.
  • - USB port for local device updates.
  • - Supports DIN rail or screw-tab mounting.
  • - Can be mounted directly to the OFBBC controller or remotely up to 500 feet away.
  • - Configurable inputs support 0–5 Vdc, 0–10 Vdc, 0–20 mA, RTD, thermistor, dry contact, or pulse counter signals.
  • - Outputs can be configured as analog or binary outputs.
  • - Analog outputs support 0–10 Vdc or 0–20 mA devices.
  • - Binary outputs feature built-in relays for switching external devices or relays up to 1A at 30 Vac/Vdc.
  • - Hand-Auto-Off switches on each output, with potentiometers for manual adjustment of analog outputs.
  • - LED status indicators for power, run, error, Xnet transmit, and Xnet receive.

Benefits:

  • - Expands the input and output capacity of OptiFlex BACnet Building Controllers.
  • - Provides multiple configurations to match the monitoring and control requirements of different HVAC systems.
  • - Allows multiple expanders to be combined for greater system flexibility.
  • - Supports flexible installation in control panels or remote locations up to 500 feet from the controller.
  • - Simplifies local device updates through an integrated USB port.
  • - Accommodates a wide variety of sensors, input devices, and controlled equipment.
  • - Provides manual output control for convenient adjustment and troubleshooting.
  • - Integrates with the WebCTRL building automation system to support building operations, energy management, occupant comfort, and sustainable building performance.
Model: FIO48u FIO88u FIO812u FIO012u